Technical data – Flowserve NRG16-41 User Manual
Page 7

7
NRG 16-41, NRG 17-41, NRG 19-41
Type Approval
TÜV · SWB / SHWS · 0-403
EG BAF-MUC 0 0 0388 00
Service pressure
NRG 16-41
NRG 17-41
NRG 19-41
3 bar g at 38 °C
60 bar g at 75 °C
00 bar g at 3 °C
Connection
Screwed ¾", EN ISO 8-
Materials
Terminal box: Die cast aluminium 3.6 (G AlSi8Cu3)
Enclosure: S. S. .457 (X6CrNiMoTi7--)
Measuring electrode: S. S. .440 (X5CrNiMo7--)
Electrode insulation: PEEK
Lengths supplied
500 mm, 000 mm, 500 mm
Sensitivity of response
> 0.5
µS/cm at 5°C.
Supply voltage
8 – 36 V DC (coming from NRS -4)
Current consumption
35 mA
Fuse
Electronic thermal fuse T
max
= 85 °C
Hysteresis
- K
Electrode voltage
V
ss
Data exchange
CAN bus to DIN ISO 898, CANopen Protocol
Indicators and adjustors
One 0-pole code switch for setting node ID and baud rate
Two LEDs “P
rograM
running
”
Two LEDs “c
an
bus
coMMunication
”
Electric connection
M sensor connector, 5 poles, A-coded,
M sensor jack, 5 poles, A-coded
Protection
IP 65 to DIN EN 6059
Max. admissible ambient temperature
70 °C
Weight
Approx. .5 kg
Technical Data