Flowserve VKP 40Ex User Manual
Page 6

6
Environmental requirements
Temperature rating for VKPN 40Ex:
Operating temperature: –0 °C to 50°C
Temperature rating for VKPS 40Ex:
Operating temperature: –0°C to 60°C
The equipment approval corresponds to protection class
“II 2G EEX ib IIC T4”:
Explosion group IIc
GAS
Category
Temperature class T4
Intrinsically safe according to “ib”
Max. operating voltage:
Data collector VKPN 40Ex: 3.3 V
Measuring transducer VKPS 40Ex: 5.0 V
Max. power consumption:
Data collector VKPN 40Ex: 0.5 A
Measuring transducer VKPS 40Ex: 0.03 A
Board with storage
battery unit
Ribbon cable
➞
➞
Lower part of VKPN 40Ex
Safety Notes for VKP 40Ex
– continued –
Replacing storage battery unit of VKPN 40Ex
– continued –
Gasket
➞
Data collector VKPN 40Ex (opened)