If the sound level reaches or falls below the threshold value of the sound level during a test before 0 seconds have elapsed, the test
will be automatically finished after 0 seconds. Otherwise the test takes 0 seconds.
After the test the test result will be shown:
Checking Steam Traps
– continued –
Test
– continued –
Possible evaluations:
OK: Yes Trap works without steam loss
OK: No Trap defective
OK: BC
Banking-up of condensate possible (only if the service pressure has been specified on the PC)
OK: FN
Trap influenced by foreign noise (see section “Foreign noise”)
For more information refer to section
“Evaluation criteria” and “Evaluating steam traps” in the Online Documentation.
If you want to repeat the test, use the down arrow button and then press the ENTER key. (The display shows again the graphical
respresentation with the limit and threshold sound values LV and TV in the form of horizontal lines).
To save the test result press the ENTER key.
After saving the test results the task list appears. Checked steam traps are ticked off
✓
.
➔
The next steam trap to be tested is marked in the list with the symbol .
▲
Test result