Datalogic Scanning QUICKSCAN QD 2300 User Manual
Page 40
RS-232
34
QuickScan
®
L
Table 6. Terminal Specific RS-232
Parameter
Standard
(Default)
ICL
Fujitsu
Wincor-
Nixdorf
Mode A
Wincor-
Nixdorf
Mode B/
OPOS
Olivetti
Omron
Transmit
Code ID
No
Yes
Yes
Yes
Yes
Yes
Yes
Data Transmis-
sion Format
Data as is
Data/Suffix
Data/Suffix
Data/Suffix
Data/Suffix
Prefix/Data/Suf-
fix
Data/Suffix
Suffix
CR/LF
(7013)
CR (1013)
CR (1013)
CR (1013)
CR (1013)
ETX (1002)
CR (1013)
Baud Rate
9600
9600
9600
9600
9600
9600
9600
Parity
None
Even
None
Odd
Odd
Even
None
Hardware Hand-
shaking
None
RTS/CTS
Option 3
None
RTS/CTS
Option 3
RTS/CTS
Option 3
None
None
Software Hand-
shaking
None
None
None
None
None
Ack/Nak
None
Serial Response
Time-out
2 Sec.
9.9 Sec.
2 Sec.
9.9 Sec.
9.9 Sec.
9.9 Sec.
9.9 Sec.
Stop Bit
Select
One
One
One
One
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
8-Bit
8-Bit
7-Bit
8-Bit
Beep On
Disable
Disable
Disable
Disable
Disable
Disable
Disable
RTS Line
State
Low
High
Low
Low
Low = No data
to send
Low
High
Prefix
None
None
None
None
None
STX (1003)
None
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.
**If Nixdorf Mode B is scanned without the scanner connected to the proper host, it may appear unable to scan. If this happens, scan a
different RS-232 host type within 5 seconds of cycling power to the scanner.
Table 7. Terminal Specific Code ID Characters
ICL
Fujitsu
Wincor-
Nixdorf
Mode A
Wincor-
Nixdorf
Mode B/OPOS
Olivetti
Omron
UPC-A A
A
A
A
A
A
UPC-E E
E
C
C
C
E
EAN-8/JAN-8 FF
FF
B
B
B
FF