6 completing installation, Cartridge in place (dry side) figure 14 – Flowserve SLM-6000 User Manual
Page 9
9
Cartridge in Place (Dry Side) Figure 14
6 Completing Installation
6.1 Evenly tighten the Socket Head Cap Screws of the 2-piece split clamp collar, the Hex
Head Cap Screws of the 3-piece shrink disk collar, or the Set Screws of the 1-piece
sleeve collar to the proper torque values listed below.
TORQUE VALUES
ft-lbs
(N-m)
Split Clamp Shrink Disk Set Screw Set Screw Penetrating
Clamp
Clamping
(Cup Point)
(Dog Point)
Fastener Alloy Steel Alloy Steel Alloy Steel Stainless Alloy
Size
Steel Steel
1/4”
10-12 4-6 7-8
(14-16)
(5-8)
(9-11)
5/16”
24-26
20-22
10-12
13-15
(33-35)
(27-30)
(14-16)
(18-20)
3/8”
40-45
24-27
18-20
22-25
(54-61)
(33-37)
(24-27)
(30-34)
1/2”
90-100
50-55
(122-136)
(68-75)