5 dry-side (bearing-side) installation – Flowserve SLM-6000 User Manual
Page 7
7
Cartridge in Place (Wet Side) Figure 10
Slide Cartridge onto Shaft Figure 11
Push on Gland to Slide the
Seal Over the Shaft/Sleeve
Do Not Hammer or
Push on Seal Sleeve
Do Not Hammer or
Push on Seal Sleeve
Push on Flange/Gland to Slide
the Seal Over the Shaft/Sleeve
4.7 Insert the retaining screws through the rear face of the pump case and screw into the
seal gland. Tighten the retaining screws evenly to pull the seal into the pump case.
See Figure 10.
5 Dry-Side (Bearing-Side) Installation
The following steps describe installation of the seal cartridge mounted on the dry,
or bearing, side of the equipment case. If your cartridge is designed to mount on the wet,
or impeller, side of the equipment case, refer to section 4. If you have completed section 4,
skip to section 6.
5.1 With the seal clamp collar facing toward the bearing assembly, slide the complete
cartridge over the pump shaft/sleeve and push back toward the bearing housing.
See Figure 11.
Warning: Do not hammer on or push against the cartridge sleeve.