4.4 If the seal is mounted directly on the shaft, rather than on the equipment sleeve, install

the impeller spacer sleeve (possibly modified).

4.5 Install the impeller and case.

4.6 Make any necessary impeller adjustments.

Warning: Loosen the bearing assembly and drive belts only enough to make the

adjustments. Fully retighten the bearing assembly and belts after adjustment.

6

4.3 It is advisable to hold the gland gasket in place in the gland groove with contact

adhesive, #404 “super glue” (in spots only), or vacuum grease. With the seal clamp

collar facing toward the bearing assembly, slide the complete cartridge over the

pump shaft/sleeve and push back into the pump case. See Figure 9.

Warning: Do not hammer on or push against the cartridge sleeve.

Do not secure the gland retaining screws to the equipment casing at this time.

Check Seal Chamber Concentricity Figure 8

0.38 mm (0.015") Maximum Seal

Chamber Concentricity Runout

Inserting Cartridge Figure 9

Push on Gland to Slide the

Seal over the Shaft/Sleeve

Do Not Hammer or

Push on Seal Sleeve

Do Not Hammer or

Push on Seal Sleeve

Push on Gland to Slide

the Seal over the Shaft/Sleeve