2transport and storage, 1 consignment receipt and unpacking, 2 handling – Flowserve CPXS User Manual
Page 10: 3 lifting

CPXS, CPXNS and CPXPS USER INSTRUCTIONS ENGLISH 71569250 07-11
Page 10 of 48
flowserve.com
Typical sound pressure level L
pA
at 1 m reference 20
µ
Pa, dBA
3 550 r/min
2 900 r/min
1 750 r/min
1 450 r/min
Motor size 
and speed 
kW (hp)
Pump
only
Pump and
motor
Pump
only
Pump and
motor
Pump
only
Pump and
motor
Pump
only
Pump and
motor
<0.55(<0.75)
72
72
64
65
62
64
62
64
0.75 (1)
72
72
64
66
62
64
62
64
1.1 (1.5)
74
74
66
67
64
64
62
63
1.5 (2)
74
74
66
71
64
64
62
63
2.2 (3)
75
76
68
72
65
66
63
64
3 (4)
75
76
70
73
65
66
63
64
4 (5)
75
76
71
73
65
66
63
64
5.5 (7.5)
76
77
72
75
66
67
64
65
7.5 (10)
76
77
72
75
66
67
64
65
11(15)
80
81
76
78
70
71
68
69
15 (20)
80
81
76
78
70
71
68
69
18.5 (25)
81
81
77
78
71
71
69
71
22 (30)
81
81
77
79
71
71
69
71
30 (40)
83
83
79
81
73
73
71
73
37 (50)
83
83
79
81
73
73
71
73
45 (60)
86
86
82
84
76
76
74
76
55 (75)
86
86
82
84
76
76
74
76
75 (100)
87
87
83
85
77
77
75
77
Note: for 1 180 and 960 r/min reduce 1 450 r/min values by 2 dBA. For 880 and 720 r/min reduce 1 450 r/min values by 3 dBA. 
 
 
2
TRANSPORT AND STORAGE
2.1 Consignment receipt and
unpacking
Immediately after receipt of the equipment it must be 
checked against the delivery/shipping documents for 
its completeness and that there has been no damage 
in transportation. Any shortage and/or damage must 
be reported immediately to Flowserve Pump Division 
and must be received in writing within one month of 
receipt of the equipment. Later claims cannot be 
accepted. 
 
Check any crate, boxes or wrappings for any 
accessories or spare parts that may be packed 
separately with the equipment or attached to side 
walls of the box or equipment. 
 
Each product has a unique serial number. Check 
that this number corresponds with that advised and 
always quote this number in correspondence as 
well as when ordering spare parts or further 
accessories. 
 
2.2 Handling
Boxes, crates, pallets or cartons may be unloaded 
using fork lift vehicles or slings dependent on their 
size and construction. 
 
2.3 Lifting
A crane must be used for all pump sets in
excess of 25 kg (55 lb). Fully trained personnel 
must carry out lifting, in accordance with local 
regulations. 
 
Slings, ropes and other lifting gear should be 
positioned where they cannot slip and where a 
balanced lift is obtained. The angle between two 
load carrying slings or ropes must not exceed 60° 
 
2.3.1 
Bare pump
The bare pump should be lifted as shown: 
 