7 faults; causes and remedies, 1 faults on the pump – Flowserve MEN User Manual
Page 31

MEN
USER INSTRUCTIONS ENGLISH 71576288 – 11-09
Page 31 of 36
®
7 FAULTS; CAUSES AND REMEDIES
7.1 Faults on the pump
Insufficient flow rate
Irregular pump running
Driver overloaded
Mechanical seal leak
Equipment vibration
Excessive pump casing temperature
POSSIBLE CAUSES
SOLUTIONS
x
x
x X Pump or suction pipe not completely filled
- Check and complete filling
X X
X Air bubbles in pipes
- Check and desecrate the pipes
X
X X Suction level too low
- Check: the available NPSH > the required NPSH
- Reduce geometrical suction lift
- Reduce head losses in pipes and in fittings (diameter
increase and appropriate fitting positions)
- Check valves and strainers
- Check the immersion head of the suction valve
X
X Total manometric head system higher than
pump differential head
- Check the discharge head
- Check the head losses in discharge pipes (partly closed valve,
foreign particles, back pressure too high)
- Modify the installation or change the pump set
X
X Total manometric head system lower than
pump differential head
-Throttle at discharge valve or trim the impeller (contact our
local agent) CONSULT FLOWSERVE
X
X X Pipes (valves, filter...)
- Control, dismantle and clean
X X Insufficient flow rate
- Check the suction and discharge pipes (valves, back
pressure)
X
Worn wear-ring surfaces
- Foresee pump mending. CONSULT FLOWSERVE
X X X X Seizure, jamming
- CONSULT FLOWSERVE
X X X X Excessive strains on flanges
- Check the flange connections and eliminate strains (pipe
positioning or elastic sleeves mounting)
X
Defective gland packing on the shaft
- Check and replace all the gland packing parts
- Mechanical seal: CONSULT FLOWSERVE
X X X X Defective motor bearings
- CONSULT FLOWSERVE
X
X Specific gravity or viscosity of liquid too high
- Consult our local agent to analyze the problem
X Misalignment
- Check the alignment of the pump and of its driver
X Foundations not sufficiently rigid
- Check the setting of base plates: tightening, bad adjustment,
seal
Insufficient pressure
Pump looses prime after starting
POSSIBLE CAUSES
SOLUTIONS
X X Presence of air
- Check and de-aerate
x
Suction pressure insufficient
- Check: the available NPSH > the required
NPSH
X
Mechanical defects
- CONSULT FLOWSERVE
X Air leak in the suction pipe
- Check suction pipe is airtight
X Restriction in suction pipe
- Check diameter of suction pipe
X Suction level too low
- Check the NPSH >NPSH
- Reduce geometrical suction lift
- Reduce head losses in pipes and in fittings
(diameter increase and appropriate fitting
positions)
- Check valves and strainers
- Check the immersion head of the suction valve
X Obstruction of suction pipe
- Check condition of pipe
X Defective gland packing on the shaft
- Check and replace all the gland packing.
- Mechanical seal: CONSULT FLOWSERVE
X Defective gasket