WPG and WPH USER INSTRUCTIONS ENGLISH 26999969 10-12
Page 9 of 40
flowserve.com
1.8.2 Ecodesign 
EU regulation 547/2012 of the Directive 
2009/125/EC, for the minimum efficiency of defined 
classes of water pumps requires that products must 
show their Minimum Efficiency Index (MEI) value. 
The EU benchmark MEI 
≥ 0.70. Also product
information must be available to users. 
 
Performance curves will have been provided with the 
quotation or order or are available at flowserve.com. 
 
The efficiency of a pump with trimmed impeller is 
usually lower than that of a pump with the full impeller 
diameter. Trimming of the impeller will adapt the 
pump to a fixed duty point, leading to reduced energy 
consumption. The minimum efficiency index (MEI) is 
based on the full impeller diameter. 
 
The operation of this water pump with variable duty 
points may be more efficient and economic when 
controlled by, for example, by the use of a variable 
speed drive that matches the pump duty to the system. 
 
Information on benchmark efficiency is available at; 
 
1.9 Noise level
Attention must be given to the exposure of personnel 
to the noise, and local legislation will define when 
guidance to personnel on noise limitation is required, 
and when noise exposure reduction is mandatory. 
This is typically 80 to 85 dBA. 
 
The usual approach is to control the exposure time to 
the noise or to enclose the machine to reduce emitted 
sound. You may have already specified a limiting 
noise level when the equipment was ordered, 
however if no noise requirements were defined, then 
attention is drawn to the following table to give an 
indication of equipment noise level so that you can 
take the appropriate action in your plant. 
 
Pump noise level is dependent on a number of 
operational factors, flow rate, pipework design and 
acoustic characteristics of the building, and so the 
values given are subject to a 3 dBA tolerance and 
cannot be guaranteed. 
 
 
 
 
Motor size 
and speed 
kW (hp)
Typical sound pressure level L
pA
at 1 m reference 20 μPa, dBA
3 550 r/min
2 900 r/min
1 750 r/min
1 450 r/min
Pump
only
Pump and
motor
Pump
only
Pump and
motor
Pump
only
Pump and
motor
Pump
only
Pump and
motor
<0.55 (<0.75)
72
72
64
65
62
64
62
64
0.75 (1)
72
72
64
66
62
64
62
64
1.1 (1.5)
74
74
66
67
64
64
62
63
1.5 (2)
74
74
66
71
64
64
62
63
2.2 (3)
75
76
68
72
65
66
63
64
3 (4)
75
76
70
73
65
66
63
64
4 (5)
75
76
71
73
65
66
63
64
5.5 (7.5)
76
77
72
75
66
67
64
65
7.5 (10)
76
77
72
75
66
67
64
65
11 (15)
80
81
76
78
70
71
68
69
15 (20)
80
81
76
78
70
71
68
69
18.5 (25)
81
81
77
78
71
71
69
71
22 (30)
81
81
77
79
71
71
69
71
30 (40)
83
83
79
81
73
73
71
73
37 (50)
83
83
79
81
73
73
71
73
45 (60)
86
86
82
84
76
76
74
76
55 (75)
86
86
82
84
76
76
74
76
75 (100)
87
87
83
85
77
77
75
77
90 (120)
87
88
83
85
77
78
75
78
110 (150)
89
90
85
87
79
80
77
80
150 (200)
89
90
85
87
79
80
77
80