3 lifting, 4 storage – Flowserve MENBLOC 60Hz User Manual
Page 12

MENBLOC 60Hz USER INSTRUCTIONS ENGLISH 71559945 - 02/13
Page 12 of 36
flowserve.com
2 Poles
North America
Metric
Unit
mass
Motor
mass
MENBLOC (Hp)
MENBLOC (kW)
kg
lb
kg
lb
2 x 1¼ - 5-2
50-32-125/1.2-2
28
62
13
29
2 x 1¼ x 6-3
50-32-160/2.2-2
46
101
21
46
2 x 1¼ x 6-5
50-32-160/3-2
49
108
24
53
2 x 1¼ x 8-5
50-32-200/4.6-2
57
126
29
64
2 x 1¼ x 8-10
50-32-200/6.5-2
79
174
41
90
2 x 1¼ x 8L-10
50-32-200L/8.5-2
82
181
49
108
2 x 1¼ x 8L-20
50-32-200L/13-2
100 220
67
148
2½ x 1½ x 5-3
65-40-125/2.2-2
44
97
21
46
2½ x 1½ x 5-5
65-40-125/3-2
47
104
24
53
2½ x 1½ x 6-5
65-40-160/4.6-2
55
121
29
64
2½ x 1½ x 8L-10
65-40-200L/8.5-2
83
183
49
108
2½ x 1½ x 8L-20
65-40-200L/13-2
101 223
67
148
2½ x 1½ x 10-20
65-40-250/13-2
108 238
67
148
2½ x 1½ x 10-20
65-40-250/16-2
119 262
78
172
2½ x 1½ x 10L-25 65-40-250L/18.5-2* 200 441 137 302
2½ x 1½ x 10L-30
65-40-250L/22-2*
220 485 150 331
2½ x 1½ x 10L-40
65-40-250L/30-2*
298 657 233 514
2½ x 2 x 5-5
65-50-125/3-2
49
108
24
53
2½ x 2 x 5-5
65-50-125/4.6-2
54
119
29
64
2½ x 2 x 6-5
65-50-160/4.6-2
63
139
29
64
2½ x 2 x 6-10
65-50-160/6.5-2
75
165
41
90
2½ x 2 x 8L-25
65-50-200L/18.5-2* 189 417 137 302
2½ x 2 x 8L-30
65-50-200L/22-2*
220 485 150 331
2½ x 2 x 10L-40
65-50-250L/30-2*
297 655 233 514
3 x 2½ x 5-5
80-65-125/3-2
53
117
24
53
3 x 2½ x 5-5
80-65-125/4.6-2
58
128
29
64
3 x 2½ x 5-10
80-65-125/6.5-2
70
154
41
90
3 x 2½ x 6-20
80-65-160/13-2
103 227
67
148
3 x 2½ x 6-20
80-65-160/16-2
114 251
78
172
3 x 2½ x 8L-30
80-65-200L/22-2*
221 487 150 331
3 x 2½ x 8L-40
80-65-200L/30-2*
295 650 233 514
3 x 2½ x 8L-50
80-65-200L/37-2*
312 688 249 549
4 x 3 x 6-20
100-80-160/13-2
106 234
67
148
4 x 3 x 6-20
100-80-160/16-2
117 258
78
172
4 x 3 x 8L-30
100-80-200L/22-2* 244 538 150 331
4 x 3 x 8L-40
100-80-200L/30-2* 311 686 233 514
4 x 3 x 8L-50
100-80-200L/37-2* 328 723 249 549
* IP 55 motor (added pump shaft)
Pieces below 25 kg (55 lb) can be manually
handled but operators should wear protection gloves
and exercise caution.
2.3 Lifting
2.3.1 Slinging of motor pumps units
Use handling means in accordance with motor
pump unit mass mentioned on the CE plate. For the
masses of the pumps bare end of shaft see table §
2.2.2 and nameplate.
To avoid distortion, the pump unit
should be lifted as shown.
A crane must be used for all pump sets in
excess of 25kg (55 Ib). Fully trained personnel must
carry out lifting, in accordance with local regulations.
Motor pump unit
When handling always wear gloves, safety
boots and an industrial safety helmet.
For masses above 25 kg (55 lb), manual
handling is forbidden.
2.4 Storage
Store the pump in a clean, dry
location away from vibration. Leave piping
connection covers in place to keep dirt and other
foreign material out of pump casing. Turn pump at
intervals to prevent brinelling of the bearings and the
seal faces, if fitted, from sticking.
Do not store pumps starting on the fan guard.
The pump may be stored as above for up to 6
months. Consult Flowserve for preservative actions
when a longer storage period is needed.
The pump must be stored in a non explosive,
ventilated location, sheltered from bad weather, dust
and vibrations.