ETA Digi Lancetta User Manual
Page 28

V. REMOVING PROBLEMS
Problem
Cause
Solution
Iron is not heated.
Power supply not connected Check the cord, plug and the socket
Display shows STAND-BY
Set suitable program with control
sign
AUTO STOP function
Move the iron for deactivation of the
activated
safety function
Iron does not create
There is no water in the
Pour water into the container
steam
container
Steaming regulator is
Move the regulator into the steaming
in 0 position
position
Low temperature is set for
Set a program by the control, during
activating the DRIP-STOP
which you can use steaming and wait till
function
the iron is heated for using it
Iron does not create
Low temperature is set for
Set a program by the control, during
steam shock
activating DRIP-STOP
which you can use steaming and wait till
function
the iron is heated for using it
The function of steam shock Let the iron heat and wait for a while
was used too often during
before using the electric shock function
a short period of time
again
Sprinkling equipment
There is no water in the
Pour water into the container
(additional spray) does
container
not sprinkle water
The water system is aerated Tighten finger on the additional spray
jet hole and at the same time press the
sprinkling device button several times
Water is dripping from
The lid of the pouring hole of Close the pouring hole lid
the ironing plate
the container is not closed
properly.
Low temperature is set
Set a program by the control, during
which you can use steaming and wait till
the iron is heated for using it
The steam shock function
Set the program COTTON, MAX or PWR
was used when temperature JEANS by the control
below
was set
28