the device connected to the Word Clock input is configured as clock master. You can choose
between FS (Word Clock) or 256FS (Super Clock) settings.
5.4.3 I/O Config
Analog: This where you adjust the analog output level of the analog output channel of the MaXiO
PCI/PCIe host card. This analog output is only available when you have connected a device to the
M.D.I port with analog outputs (such as the MaXiO 032 breakout box).
S/PDIF: this can be Pro, which means that actually an AES/EBU signal with the ‘professional’
status bit set is transferred via the S/PDIF I/O of the MaXiO PCI/PCIe host card (via the M.D.I
connection, e.g. the M.D.I breakout cable), or it can be Consumer, which means that normal S/PDIF