5 adjusting nozzle height, 6 attaching/emptying the bag – Echo Bear Cat WV190S 2009 User Manual
Page 14

WHEELED VACUUM
10
OPERATION
using the height adjustment cable:
The nozzle can be adjusted between five different height
settings by using the height adjustment cable on the
Vacuum handlebar. To do so, pull the height adjustment
cable. Adjust the Vacuum to the desired position and
release the cable to lock the vacuum in position.
Height adjustment bracket:
The height of the fan intake housing can be set by adjusting
the height adjustment bracket (Figure 4.4). The bracket is
located by the front right hand wheel and is mounted to the
frame with two 1/4" carriage bolts. To adjust the bracket:
Use the height adjustment cable to lower the fan intake
1.
housing to the lowest position (see above).
Loosen the 1/4" nuts of the height adjustment bracket.
2.
Make sure the bracket can slide on the frame.
Adjust the height of the Vacuum fan intake housing
3.
to the desired position using the slotted holes. The
recommended distance is 1/2" above ground level. in
sandy conditions, the nozzle can be lowered further.
once the position has been set, torque the nuts to 9
4.
ft-lbs.
Check the machine to ensure it is level and at the
5.
proper height. Adjust if necessary using the above
procedure.
Figure 4.4, Height adjustment bracket
attaching the bag:
Place the loops of the vacuum bag into the bag hanger
1.
brackets on the handlebars.
lift the exhaust door.
2.
attach the bag handle into the vacuum discharge.
3.
Emptying the bag:
Shut the engine off.
1.
lift the bag handle and pull the bag out of the discharge.
2.
The spring loaded exhaust door will close.
remove the two bag loops from the bag hanger
3.
brackets.
open the main zipper in the side of the bag.
4.
remove the debris from the bag.
5.
Close the zipper, being careful not to let debris become
6.
lodged in the zipper teeth.
4.6 aTTacHING/EmpTYING THE baG
NoTE
use the bag at all times.
•
empty the bag before it fills completely. a full
•
bag will cause performance to decrease or stop
completely.
empty bag completely before storage.
•
Keep bag clean by occasionally washing it with mild
•
soap and water.
4.5 adjuSTING NozzLE HEIGHT
- WV190 2009 WV179S 2009 WV179 2009 WV160S 2009 WV160 2009 WV190S 2008 WV190 2008 WV179S 2008 WV179 2008 WV160S 2008 WV160 2008 77360 77060 75360 2008 75060 2008 WV190S 2010 WV160S 2010 WV160 2010 WV190S 2014 WV190 2014 WV160S 2014 WV160 2014 WV190S 2011 WV190 2011 WV160S 2011 WV160 2011 WV190S 2013 WV190 2013 WV160S 2013 WV160 2013 WV190 2010