Codes for setpoint values – Digi-Star TCX-1000 SERIES User Manual
Page 29

D3556 05/29/03 REV. 2.2
Copyright 2001
29
Lit=1.0
Backlight 1 minute
Lit=2.0
Backlight 2 minutes
Lit=5.0
Backlight 5 minutes
1st Security Code
SC1=00 Code
Disabled
00 00 00
SC1=xx
xx = 01 to 99 : Set security
Code #1
2
nd
Security Code
SC2=00 Code
Disabled
00 00 00
SC2=xx
xx = 01 to 99 : Set Security
Code #2
Note: Be sure to record both Security Codes somewhere for safekeeping. If they are lost the
indicator will have to be returned to the factory to have the codes reset to 00. After pressing the
enter key to enter the last configuration menu step, the display will show SEtPntS.
D.
SETPOINT SETUP
With the display showing SetPntS, press the Enter key to display the current setpoint #1 Mode, or
repeat ESC to cycle through the calibration menus.
Display Step
S1:__
SETPOINT #1 MODE
S2:__
SETPOINT #2 MODE
S3:__
SETPOINT #3 MODE
S4:__
SETPOINT #4 MODE
S5:__
SETPOINT #5 MODE
S6:__
SETPOINT #6 MODE
S7:__
SETPOINT #7 MODE
S8:__
SETPOINT #8 MODE
Codes for setpoint Values
Display Legal
Values
oFF
Setpoint Disabled
grHi
Setpoint Gross Weight High
ntHi
Setpoint Net Weight High
grLo
Setpoint Gross Weight Low
ntLo
Setpoint Net Weight Low
drib
Setpoint acts as dribble