Digi-Star StockWeigh 500 User Manual
Page 8

StockWeigh 500
D3632 US-B
4
LKNHLD
(Lock-N-Hold) This feature continues to "hold" the "Lock-On”
weight on the display for an animal after it has stepped off the
weighing platform.
This allows the operator to place the animal on the weighing
platform, medicate, remove the animal from the platform and then
record the animal's weight after it has stepped off the platform.
The display will restart once another animal has stepped onto the
platform and exceeds 2.5% of the scale capacity. For example if
the scale capacity is set at 4000lbs (StockWeigh 3300), 100lbs is
required to reset the display. The indicator will return to normal
weighing after 5 minutes if no other animal steps on the weighing
platform. The Recheck key can also be used to return the indicator
to the weighing mode.
AUTOFF
(Auto Off) This feature allows the operator to have the indicator
automatically shut itself “OFF” after either 15, 30, 45 or 60
minutes of inactivity.
This feature will extend battery life on portable scales operating
off batteries. Prior to the scale shutting OFF, the message
“GOODBYE” will be scrolled across the display for approximately
15 seconds. Pressing a key on the indicator during this time will
prevent the unit from turning off and restart the internal "shut off
timer" with the time selected in "AUTOFF".
COUNT
(Display Count) Indicator displays count in increments of 0.01,
0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, and 100.
Note:
If the count is set too small for the calibration, the readings
will be unstable and the indicator will not be accurate.
ARANGE
(Auto-Range)
If “ON” the scale increases display count size for
weights over 300 and again at 600 lbs/kgs. If set to “OFF”
display counts are set and do not vary.
For example: 0 to 300 lbs (1 lb Increment), 300 to 600lbs. (2 lbs
Increments), 600 and up (5 lbs. Increments).
LB-KG
(Display Unit) Select desired weight unit to be displayed.
When changing weight unit using the long form, calibration is
adjusted so the scale displays accurately in the new display unit.