4
To Recheck Lock-On Weight
While the animal is still on the scale platform, press the [ZERO/RECHECK] key to “RECHECK” or
recalculate the weight of the animal. This is the weight that will be printed and/or stored when the
animal steps off of the scale platform or the [ON/RECORD] key is pressed.
Low Battery Indication
If the supply voltage drops below the (10.5 Volts), the message “
RECHARGE BATTERY -
TURNING OFF” and “LO BAT” will periodically show on the display to alert the operator of the
low battery condition. After 2 minutes the indicator will shut off.
WARNING:
Disconnect the indicator from the battery while recharging. DAMAGE CAN
OCCUR to the indicator and the stick reader.
Self Test
Press [NET/GROSS] then [ON/Record] during normal system operation to start the self-test.
Memory Full Indication
Memory capacity is 1536 lines of data. When memory is 90% full, a warning message will
periodically scroll across the screen.
Optional Settings
The Indicator has optional settings that allow flexibility in the way that the scale is used and data is
collected.
Change Setup for Load Cells.
The indicator setup and calibration numbers need to be modified when changing load cell type.
Follow the steps below to change the setup and calibration numbers.
Enter the “Short Form Calibration Selection” menu by holding [Zero] and pushing [On/Off] for three
seconds.
Press [Gross/Net] to advance through the following selections.
3300LB
StockWeigh 3300 with Lock On (pounds)
6600LB
StockWeigh 3300 with Lock On (pounds)
10K LB
StockWeigh 10000 with Lock On (pounds)
14K LB
StockWeigh 14000 with Lock On (pounds)
3300KG
StockWeigh 3300 with Lock On (kilograms)
6600KG
StockWeigh 3300 with Lock On (kilograms)
10K KG
StockWeigh 10000 with Lock On (kilograms)
14K KG
StockWeigh 14000 with Lock On (kilograms)
CUSTOM
Any other load cell. See “Short Form Calibration” in Appendix “A”
for detailed instructions.
Press [On/Off] to save desired load cell calibration and exit.
NOTE:
If the indicator is not set for weigh method 4 or 8, “Lock-On Weigh Method” the indicator will