Appendix d, Operators manual, Short form calibration – Digi-Star StockWeigh 550 EID User Manual
Page 23
Operators Manual
D3645
19
Appendix D
Short Form Calibration
NOTE:
For systems with Digi-Star StockWeigh Load Cells see page 5 for setup instructions.
The Short Form Setup & Calibration procedure allows you to change the “SETUP” and “CAL”
numbers of the indicator.
Setup Number
The “SETUP” numbers affects some parameters that also appear in the Long Form Calibration.
Following is a list of functions that are controlled by the “SETUP” number:
Weigh Method (W MTHD)
Display Units (LB-KG)
Display Counts (COUNT)
Gain
Scale Capacity
Calibration Number
The “CAL” number is adjusted to make the scale read the proper weight for different load cells and
to make accuracy adjustments on a scale system.
If a StockWeigh 550 EID indicator is provided with StockWeigh load cells as a package, the
calibration number is adjusted at the factory for maximum accuracy. Systems that are assembled
from separate components are given “STANDARD SETUP AND CALIBRATION NUMBERS” and
are not factory calibrated. These systems should be checked and adjusted if necessary using
known weights to insure accuracy. See “Calibrating the Scale for Maximum Accuracy” below.
Following is a list of Standard Setup and Calibration numbers for StockWeigh 3300, 6600 and
14000 load cells. If you are not using StockWeigh load cells, contact Digi-Star Tech Support at
920-563-9700 for setup and calibration information:
Scale Type
Unit
Setup #
Calibration #
StockWeigh
3300
Lb
413004
776
StockWeigh
6600
Lb
413007
1560
StockWeigh
14000
Lb
443015
13828
StockWeigh
3300
Kg
812002
352
StockWeigh
6600
Kg
812003
708
StockWeigh
14000
Kg
843007
6272