SHORT FORM CALIBRATION
Short Form Setup & Calibration procedure allows changing “SETUP” and
“CAL” numbers of indicator.
Setup Number
The “SETUP” numbers affects some parameters that also appear in Long
Form Calibration. Following is a list of functions controlled by “SETUP”
number:
Weigh Method (W MTHD)
Display Units (LB-KG)
Display Counts (COUNT)
Gain
Scale Capacity
Calibration Number
The “CAL” number adjusted to make scale read proper weight for different
load cells and to make accuracy adjustments on scale system. If a
StockWeigh indicator provided with StockWeigh load cells as a package,
calibration number adjusted at factory for maximum accuracy. Systems
that are assembled from separate components are given “STANDARD
SETUP AND CALIBRATION NUMBERS” and are not factory calibrated.
These systems should be checked and adjusted if necessary using known
weights to insure accuracy. See “Calibrating the Scale for Maximum
Accuracy” below.
List of Standard Setup and Calibration numbers for StockWeigh 3300,
6600, 10000 and 14000 load cells shown below. If not using StockWeigh
load cells, contact Digi-Star Tech Support at 920-563-9700 for setup and
calibration information:
StockWeigh
Scale Type
Unit
Setup #
Calibration #
3300
Lbs
413004
776
6600
Lbs
413007
1560
10000
Lbs
454010
14000
14000
Lbs
443015
13828
3300
Kg
812002
352
6600
Kg
812003
708
10000
Kg
854010
6351
14000
Kg
843007
6272