D3715-GB Rev E EZ3600 User's manual
38
Connecting load cells to J-Box
Figure4: J-Box connections
Changing setup and calibration numbers
[
SETUP] & [CAL]
1. Enter 871.
2. Press .
3. Weighing indicator briefly shows
SETUP
followed by a six digit number. Enter the
new number.
4. Press
.
Use 872 and follow the same procedure to
change the calibration
CAL number.
Tighten nuts
Load cell cable
J-Box cable
Connect to bottom panel of weighing
indicator. See figure 3.
1/3
2
SETUP
4
3
Connection of wires from
load cell cable to terminals.
Wire colours
Pin Colour
Description
1 Red
Excitation +
2 Green
Signal -
3 White
Signal +
4 Black
Excitation -
4 Transparent
Shield
J-Box with 4 load cell
connections