beautypg.com

Digi-Star EZ 3600V Manual USB User Manual

Page 36

background image

List with direct access numbers

D3715-GB Rev E EZ3600 User's manual

33

Setting

[display]

Access

Options [displayed]

(bold=default)

Description

UNCOMPLETED RECIPES

[

UNDN I]

455

ON/OFF

If this setting is

ON, the weighing

indicator displays all uncompleted

recipes.

AUTOSTART GROUPS

[

AUTPEN]

458

ON/OFF

If this setting is

ON, the group list will

automatically appear on the display

after loading the ingredients.

MANUALLY ADVANCING
TO NEXT GROUP[

MANPEN]

461

ON/OFF

If this setting is

ON, the operator

should manually advance to the

next group(s) to be fed.

GROUP TOLERANCE

[

T MTHD] & [PENTOL]

462

WEIGHT

PERCNT

Select WEIGHT or PERCNT and

enter of group tolerance.

DISPLAYED WEIGHT

DURING FEEDING

[

PEN WT]

463

LOAD

GROSS

NET

The method of displaying during

feeding: net, load or gross weight.

DOUBLE KEY PRESS PREV

[

DBLKEY].

465

ON/OFF

Select if a double key press should

be ignored during loading and

feeding.

RECIPE REMAINS ACTIVE

[

RE-USE]

466

ON/OFF

Select ON to re-use recipes.

CALIBRATION

SETUP NUMBER

[

SETUP]

871

The unit of weight (1-4lbs or 5-8

kg), the gain (1-9), the sensitivity

(display counts 1-9) and the

capacity * 1000 can be entered

using direct number entry.

CALIBRATION NUMBER

[

CAL]

872

Displayed amount at 0.4mV/V for

these load cells.