List with direct access numbers
D3715-GB Rev E EZ3600 User's manual
33
Setting
[display]
Access
Nº
Options [displayed]
(bold=default)
Description
UNCOMPLETED RECIPES
[
UNDN I]
455
ON/OFF
If this setting is
ON, the weighing
indicator displays all uncompleted
recipes.
AUTOSTART GROUPS
[
AUTPEN]
458
ON/OFF
If this setting is
ON, the group list will
automatically appear on the display
after loading the ingredients.
MANUALLY ADVANCING
TO NEXT GROUP[
MANPEN]
461
ON/OFF
If this setting is
ON, the operator
should manually advance to the
next group(s) to be fed.
GROUP TOLERANCE
[
T MTHD] & [PENTOL]
462
WEIGHT
PERCNT
Select WEIGHT or PERCNT and
enter of group tolerance.
DISPLAYED WEIGHT
DURING FEEDING
[
PEN WT]
463
LOAD
GROSS
NET
The method of displaying during
feeding: net, load or gross weight.
DOUBLE KEY PRESS PREV
[
DBLKEY].
465
ON/OFF
Select if a double key press should
be ignored during loading and
feeding.
RECIPE REMAINS ACTIVE
[
RE-USE]
466
ON/OFF
Select ON to re-use recipes.
CALIBRATION
SETUP NUMBER
[
SETUP]
871
The unit of weight (1-4lbs or 5-8
kg), the gain (1-9), the sensitivity
(display counts 1-9) and the
capacity * 1000 can be entered
using direct number entry.
CALIBRATION NUMBER
[
CAL]
872
Displayed amount at 0.4mV/V for
these load cells.