beautypg.com

DFI MB630-CRM User Manual

Page 31

background image

31

2

Hardware Installation

COM1/COM2 RS232/RS422/RS485 Select

1-2 On: RS232

(default)

3-4 On: RS422

Full Duplex

5-6 On: RS485

6

4

2

5

3

1

JP2 (for COM1) and JP10 (for COM2) are used to confi gure the COM ports to
RS232, RS422 (Full Duplex) or RS485.

The pin function of the COM ports will vary according to the jumper’s setting.

JP2/JP10

6

4

2

6

4

2

5

3

1

5

3

1

COM 1

COM 2

JP10

JP2

RS232

RS422

Full Duplex

RS485

COM 1 / COM 2

DCD-

TD

RD

DT

R

-

GND

1 2 3 4 5

RT

S

-

RI

-

DSR

-

CT

S-

6 7 8 9

D

ATA

+

N.C.

D

ATA

-

N.C. N.C.

1 2 3 4 5

N.C.

N.C.

N.C.

N.C.

6 7 8 9

RXD+

TXD+

RXD-

TXD- N.C.

1 2 3 4 5

N.C.

N.C.

N.C.

N.C.

6 7 8 9

This manual is related to the following products: