DFI NP102-N16C User Manual
Page 72
72
3
BIOS Setup
Hot Key Power On
This field is used to select a function key that you would like to use to pow-
er-on the system.
PWRON After PWR-Fail
Off
When power returns after an AC power failure, the system’s power is off. You
must press the Power button to power-on the system.
On
When power returns after an AC power failure, the system will automatically
power-on.
Former-Sts
When power returns after an AC power failure, the system will return to the
state where you left off before power failure occurs. If the system’s power
is off when AC power failure occurs, it will remain off when power returns.
If the system’s power is on when AC power failure occurs, the system will
power-on when power returns.
Onboard Serial Port 1/2/3/4
3F8, 2F8, 3E8, 2E8
Allows you to manually select an I/O address for the serial port.
Disabled
Disables the serial port.
Important:
The touch screen is internally connected to COM 3. If the LCD Dis-
play Panel supports touch screen, leave the “Onboard Serial Port
3” field in its default setting because a default address has already
been assigned to this port. Make sure COM 3 is not attached with a
serial device.
Serial Port 1/2/3/4 Use IRQ
These fields are used to select an IRQ for the onboard serial port 1, 2, 3 or
4.
W83627DHG.WDT Time
This field is used to select the time interval of the Watchdog timer. If the
system hangs or fails to function, it will reset at the set time interval so that
your system will continue to operate.