5
Ports and Connectors
EC200/210/220/221-LR6880
COM 3 to COM 6 RS232/RS422/RS485 Select
JP1
JP2
JP5
JP8
COM 3
(JP1)
COM 4
(JP2)
COM 5
(JP5)
COM 6
(JP8)
1-2 On: RS232
(default)
3-4 On: RS422
Full Duplex
5-6 On: RS485
6
4
2
5
3
1
JP1 (for COM 3), JP2 (for COM 4), JP5 (for COM 5) and JP8 (for COM6) are used
to confi gure the COM ports to RS232, RS422 (Full Duplex) or RS485.
The pin function of the COM ports will vary according to the jumper’s setting.
JP1 / JP2 / JP5 / JP8
6
4
2
6
4
2
5
3
1
5
3
1
COM 3 / COM 4
COM 5 / COM 6
DCD
TXD
RXD
DT
R
GND
1 2 3 4 5
6
8 9
7
DSR
CT
S
RT
S
RI
RX+
TX+
RX
-
TX
-
GND
1 2 3 4 5
6
8 9
7
N.C.
N.C.
N.C.
N.C.
D
ATA
+
N.C.
D
ATA
-
N.C.
GND
1 2 3 4 5
6
8 9
7
N.C.
N.C.
N.C.
N.C.
DT
R
RxD
CT
S
2
8
4
DCD
TxD
GND
1
3
5
RT
S
RI
7
9
DSR
6
Tx
-
Rx
-
N.C.
2
8
4
Rx+
Tx+
GND
1
3
5
N.C.
N.C.
7
9
N.C.
6
N.C.
D
ATA
-
N.C.
2
8
4
D
ATA
+
N.C.
GND
1
3
5
N.C.
N.C.
7
9
N.C.
6