Appendix b - watchdog timer, Watchdog timer – DFI EC200 Series User Manual
Page 197
197
B
Watchdog Timer
Appendix B - Watchdog Timer
Watchdog Timer
The following parameters are references for setting the time interval of the
Watchdog Timer function. The system will regularly be “cleared” according to the
set time interval. If the system hangs or fails to function, it will also reset ac-
cording to the time interval so that your system will continue to operate.
.model small
.386
;-------------------
;Port defi nation
;-------------------
SuperIo_CFG_Port EQU
2Eh
;Super I/O Confi g port. (2Eh/4Eh)
SuperIo_DAT_Port EQU
SuperIo_CFG_Port + 1
WDT_Counter
EQU
10
; 1 to 255 (Sec./Min), 0 means disabled
mSuperio_Enter_Confi g
Macro
mov
dx,
SuperIo_CFG_Port
mov
al,
87h
out
dx,
al
NEWIODELAY
out
dx,
al
endM
mSuperio_Exit_Confi g
Macro
mov
dx,
SuperIo_CFG_Port
mov
al,
0AAh
out
dx,
al
endM
mSuperio_GetSet_Reg
Macro RegIndex, AndMask, OrValue
mov
dx,
SuperIo_CFG_Port
mov
al,
RegIndex
out
dx,
al
NEWIODELAY
mov
dx,
SuperIo_DAT_Port
in
al,
dx
NEWIODELAY
mov
ah,
al
and
al,
AndMask
or
al,
OrValue
out
dx,
al
NEWIODELAY
endM
mSuperio_Get_Reg Macro RegIndex
mov
dx,
SuperIo_CFG_Port
mov
al,
RegIndex
out
dx,