DFI EC200 Series User Manual
Page 74
74
4
Jumper Settings
EC200/210/220/221-LR4G65
JP3
JP1
COM 4
(JP3)
COM 3
(JP1)
1-2 On: RS232
(default)
3-4 On: RS422
Full Duplex
5-6 On: RS485
6
4
2
5
3
1
JP1 (for COM 3) and JP3 (for COM 4) are used to confi gure the COM ports to
RS232, RS422 (Full Duplex) or RS485.
The pin function of the COM ports will vary according to the jumper’s setting.
JP1 / JP3
6
4
2
6
4
2
5
3
1
5
3
1
COM 3 / COM 4
DCD
TXD
RXD
DT
R
GND
1 2 3 4 5
RX+
TX+
RX
-
TX
-
GND
1 2 3 4 5
D
ATA
+
N.C.
D
ATA
-
N.C.
GND
1 2 3 4 5
COM 3 and COM 4 RS232/RS422/RS485 Select
6
8 9
7
DSR
CT
S
RT
S
RI
6
8 9
7
N.C.
N.C.
N.C.
N.C.
6
8 9
7
N.C.
N.C.
N.C.
N.C.