English

CODE

POSSIBLE CAUSE

POSSIBLE SOLUTION

21

Air tank pressure is too high

Open the regulator and reduce air tank pressure to less
than 40 PSI (275.8 kPa).

22

Engine problem

Contact a D

E

WALT factory service center or a D

E

WALT

authorized service center

23

Engine or pump oil is low

Add D

E

WALT synthetic compressor oil to pump. See

Compressor Pump Oil under Maintenance.

24

It is normal for some pressure drop to occur

If there is an excessive amount of pressure drop when the
accessory is used, adjust the regulator as instructed in
Regulator under Features.
NOTE: Adjust the regulated pressure under flow conditions
while accessory is being used.

25

Damaged regulator

Replace.

26

Detergent type oil being used in pump

Drain oil and refill pump with D

E

WALT synthetic compressor

oil.

27

Extremely light duty cycles

Run unit for longer duty cycles. It is recommended to run at
high throttle 50-75% of the run time and idle for 25% of the
run time.

28

Piston rings damaged or worn

Contact a D

E

WALT factory service center or a D

E

WALT

authorized service center

29

Cylinder or piston damaged or worn

Contact a D

E

WALT factory service center or a D

E

WALT

authorized service center

30

Compressor cylinder finish worn

Contact a D

E

WALT factory service center or a D

E

WALT

authorized service center

31

Water in pump oil

Drain oil and refill pump with D

E

WALT synthetic compressor

oil.