beautypg.com

Changing the ip address, Mounting options – Dataprobe iBoot-DC Quick Start User Manual

Page 2

background image

Changing the IP Address

1. Device Management Utility

Obtain the Device

Management Utility (DMU) from Dataprobe’s website at

dataprobe.com/support/iboot

.

The DMU provides the easiest

means to find and configure your iBoot-DC for use. It can
discover all the iBoots on your network, display the current IP
address of each, and allow setting of any valid IP address.

Note: The IP address can only be set within the first two
minutes of powering up the iBoot. The Setup Utility will only
work with iBoots on the same local subnets as the PC.

The iBoot-DC Setup Utility can also be used to return an iBoot-
DC to its Factory Default condition. This can be used to recover
an iBoot-DC with a lost password. Highlight an iBoot-DC from
the display and click Factory Defaults. This must also be done
within the first two minutes of powering up the iBoot.

Complete instructions for the DMU are provided with the
download, and in the full iBoot-DC Manual.

2. Web Page Setup

From the home page, click on Setup,

then Network. Enter the new IP Address, Subnet Mask and
Gateway, then click Save. Click the Reboot button (or press the
reset button next to the power outlet LED) to restart the iBoot-
DC with the new settings.

3. DHCP

From the Home page, click on Setup, then Network.

Change the IP Mode from Static to DHCP. Click Save, then
Reboot. The iBoot-DC will obtain its network settings from the
server. Check the server, or use the Device Management Utility
to obtain the new settings.




Mounting Options


iBoot-DC+ is suitable for desktop or shelf mounting. A mounting kit for
wall and DIN rail mounting is available. Order part:

1920034

Mounting Kit for iBoot-G2 Series



Fig. 5 Device Management Utility

Fig. 6 Network Setup Page

1920033 Mounting Kit

iBoot G2 Series