Specifications
WARNING
The Vortek unit must only be used with a maximum load equal to the capacity stated for the
model below. Overloading the system may result in serious injury or an inoperable system.
THE FOLLOWING MODELS ARE VARIABLE SPEED AND DESIGNATED TO BE CONTROLLED THROUGH EITHER
THE VORTEK E SERIES ENHANCED CONTROL HMI OR THE PRO SERIES VORTEK AUTOMATION CENTER
(VAC
®
). BOTH UNITS ARE STAND ALONE AUTOMATION SYSTEMS.
USA (60hz) E Series Based Models and Applications
Single Purchase
hOIST MODEl NUMBER
lOAD lb (kg)
SpEED ft/min (m/sec)
V_-0820
0-800 (362)
0-20 (0.100)
V_-12180
0-1200 (544)
0-180 (0.910)
V_-14140
0-1400 (635)
0-140 (0.700)
V_-1740
0-1750 (793)
0-40 (0.200)
V_-2020
0-2000 (907)
0-20 (0.100)
H_-22230
0-2200 (1000)
0-234 (1.200)
H_-4020
0-4000 (1814)
0-20 (0.100)
Double Purchase
hOIST MODEl NUMBER
lOAD lb (kg)
SpEED ft/min (m/sec)
V_-0820-2
0-1600 (725)
0-10 (0.050)
V_-12180-2
0-2400 (1088)
0-90 (0.450)
V_-14140-2
0-2800 (1270)
0-70 (0.350)
V_-1740-2
0-3500 (1586)
0-20 (0.100)
V_-2020-2
0-4000 (1814)
0-10 (0.050)
H_-22230-2
0-4400 (2000)
0-117 (0.600)
H_-4020-2
0-8000 (3628)
0-10 (0.050)
Maximum travel distance is 65' (19.8 m) for Single Purchase Units, 32.5' (9.9 m) for Double Purchase Units.
4