Mechanical installation, Footings and beams, Section 6 – Daktronics BA-515 User Manual
Page 23: Mechanical installation -1, Footings and beams -1

Mechanical Installation
6-1
Section 6: Mechanical Installation
Mechanical installation consists of installing concrete footings and steel beams, and mounting the
scoreboard and accompanying ad panels to the beams.
6.1
Footings and Beams
Reference Drawings:
Installation Specifications; BA 515 .......................................................... Drawing A-55003
Installation Specifications; BA 518 .......................................................... Drawing A-55004
Installation Specifications; BA 618 .......................................................... Drawing A-55006
Installation Specifications; BA 624 .......................................................... Drawing A-55007
Installation Specifications; BA 718 .......................................................... Drawing A-55005
Installation Specifications; BA 1018 ........................................................ Drawing A-61904
Installation Specifications; BA-2003...................................................... Drawing A-158322
Installation Specifications; BA-2004 & BA-2005 ................................... Drawing A-152777
Installation Specifications; FB-2340............................................................ Drawing A-169388
Installation Specifications; MS 824 ....................................................... Drawing A-127287
Installation Specifications; MS-915 ....................................................... Drawing A-113568
Installation Specifications; MS 918 ......................................................... Drawing A-55009
Installation Specifications; MS-2002 ..................................................... Drawing A-127195
Installation Specifications; MS 2002 w/TNMC ...................................... Drawing A-127195
Installation Specifications; MS-2004 ..................................................... Drawing A-128788
Installation Specifications; MS-2006 w/TNMC ...................................... Drawing A-135575
Installation Specifications; MS-2011 w/TNMC ...................................... Drawing A-135414
Installation Specifications; SO 824........................................................ Drawing A-127287
Installation Specifications; SO 918.......................................................... Drawing A-55010
Installation;
TI-2003............................................................................... Drawing A-139316
Installation Specifications; SO-2008 ..................................................... Drawing A-149074
Installation Specifications; TI-2003 ....................................................... Drawing A-169367
Installation Specifications; TI-218 ......................................................... Drawing A-169376
Installation Specifications; TI-418 ......................................................... Drawing A-169380
Refer to the installation specification drawings listed above for the rear view of each of the models.
These drawings specify the number of beams and the recommended spacing between them. It is
critical that these dimensions be adhered to for scoreboards with team name message centers because
of the ventilation hoods located on the rear of the displays.
These drawings also indicate the size of beams required to support the scoreboard at different heights
under various wind speed conditions. All of the beam specifications illustrate "W" shape steel beams
(wide-flange I-beams). The first number indicates the front-to-rear depth of the beam, and the second
number indicates the weight in pounds per foot of length.
The column and footing size dimensions provided in the drawings assist with estimating installation
costs. They are estimates only and are not intended for construction purposes. Be sure that your
installation complies with local building codes and is suitable for your particular soil and wind
conditions.