Initial operation information, Replacement parts list, Initial operation information -10 – Daktronics AF-3400-64-R,A User Manual
Page 38: Replacement parts list -10, 11 initial operation information, 12 replacement parts list

Maintenance and Troubleshooting
4-10
•
Check that the address on the light
detector is set to address 2
•
Check light detector cable.
•
Check light detector for obstructions.
•
Replace the light detector.
•
Replace the controller.
4.11 Initial Operation Information
When first operated, the display will run through an initialization in which it will
display the following:
1.
Product Name (Galaxy®)
2.
Display Size (Row x Column)
3.
Shading (64 Mono)
4.
Bootloader Version (OS X.XX)
5.
Firmware Number (ED13305)
6.
Firmware Revision (Rev X.XX)
7.
Hardware Address (HW:XX)
8.
Software Address (SW:XX)
9.
IP Address: ((default) 172.16.192.25)
10.
Subnet Msk: ((default) 255.255.0.0)
11.
COM1 Configuration (C1:V15) ((Modem C1:V15) If a Modem is present)
12.
COM2 Configuration (C2:RTD)
13.
Socket 3001: (IP 3001: V15)
14.
Socket 3002: (IP 3002: RTD)
15.
Line Frequency (CLK: AUTO (60))
16.
Display Name Description (Galaxy Row x Column)
4.12 Replacement Parts List
The following table contains some of the items in this display that may need to be
replaced over time. Many of the parts within the display also list their part numbers
on labels affixed to them.
To prevent theft, Daktronics recommends purchasing a lockable cabinet to store
manuals and replacement/spare parts.
Part Description
Part Number
Controller 0A-1229-0013
Light Detector
0P-1247-0002
Digital Temp Sensor
0P-1247-0008
Quick Connect Interface, Input
0P-1229-2004
Thermostat Enclosure
0A-1213-4024
Ribbon Assy, 20 Pos., 18”, Mod. to Mod.
W-1387
Amber Pixel Board (Check display BOM)
0P-1261-0005
Red Pixel Board (Check display BOM)
0P-1261-0003
Red Driver Board
0P-1308-0001
Amber Driver Board
0P-1308-0004
Power Supply Amber/Red, 2 Mod. (A-1555), w/harness
0A-1307-0500
Power Supply, Amber, 4 Mod., (A-1648), w/harness
0A-1307-0501