beautypg.com

Main disconnect, Main disconnect -7, Figure 16: power termination box – Daktronics AF-3400-64-R,A User Manual

Page 25

background image

Figure 16: Power Termination Box


5. Make the following connections as shown in Figure 16 for a three phase

display:

120/208 (Four wires plus Ground)

TB41

1 Phase

A

2 Phase

B

3 Phase

C

4

Neutral

E41

Ground

6. Power needs to be connected to all display faces.

Main Disconnect

The National Electrical Code requires the use of a lockable power disconnect near
the display. Provide a lockable disconnect switch (knife switch) at the display
location so all power lines can be completely disconnected. Use a disconnect to
disconnect the hot lines and the neutral. Mount the main disconnect at or near the
point of power supply connection to the display. Provide a main disconnect for each
supply circuit to the display.

You must locate the means of disconnection in a direct line of sight from the display
or outline lighting that it controls. This requirement provides protection by enabling
a worker to keep the disconnecting means within view while working on the display.

Exception: You may locate the disconnecting means that are capable of being
locked in the open position elsewhere.

Electrical Installation

3-7