Signal termination from computer to display, Signal termination between displays, Signal termination from computer to display -8 – Daktronics AF-3400-64-R,A User Manual
Page 26: Signal termination between displays -8, 6 signal termination from computer to display, 7 signal termination between displays

3.6 Signal Termination from Computer to Display
The 64mm, AF-3400 Mono display is designed for quicker signal and power
connection to the display and between displays.
• Signal will terminate to a watertight enclosure, which connects to the
primary display using a quick connect cable.
• Mounting the temperature sensor to the display structure and at least one
foot away from the display is preferred – terminate it to the primary display
with a quick connect cable (DO NOT mount the temperature sensor
between displays, or anywhere the airflow is restricted).
• If two primary displays are being used, signal and temperature sensor wires
will be connected between the controllers on each display.
A separate manual is provided for explaining the connection to the signal termination
enclosure. There are seven different methods of communication; your manual will
be one of these types:
Communication
Type
Communication
Manual ED#
RS232
ED-14739
RS422
ED-14742
Serial Fiber
ED-14743
Radio
ED-13932
Modem
ED-14744
Wire Ethernet
ED-14745
Fiber Ethernet
ED-14746
3.7 Signal Termination between Displays
Reference Drawings:
Controller, Galaxy, 8 conn., J1087 .............................. Drawing B-177838
The connection between display controllers requires a 4-conductor shielded cable for
signal. One end will connect at the “RS422 OUT” 6-position controller board
terminal block (TB3) on the first primary display, and terminate on the “RS422 IN”
6-position controller board terminal block (TB2) on the second display. Refer to
Drawing B-177838 for terminal block locations. The interconnect signal wiring
between displays is shown in Figure 17.
A cable will also need to be routed for connection between displays for the
temperature sensor if one is being used. See Appendix B for the necessary wiring of
the temperature sensor.
Primary - RS422
Out (TB3)
Field Cabling
Secondary - RS422
IN (TB2)
Pin 1 (GND)
Shield
Pin 6 (GND)
Pin 2 (D2OUT-N)
Red
Pin 5 (D1IN-N)
Pin 3 (D2OUT-P)
Black
Pin 4 (D1IN-P)
Pin 4 (D2IN-N)
Green
Pin 3 (D1OUT-N)
Pin 5 (D2IN-P)
White
Pin 2 (D1OUT-P)
Pin 6 (Shield)
Pin 1 (Shield)
Electrical Installation