For more information – Daktronics Configuring the DM-100 Gen III for Gilbarco G-Site/Passport Interface User Manual
Page 7

Configuring the DM-100 Gen III for Gilbarco
G-Site/Passport Interface Quick Guide
Page 7 of 7
DD2294804 Rev 02
13 February 2014
PO Box 5128 201 Daktronics Drive, Brookings, SD 57006-5128
tel: 800-325-8766 fax: 605-697-4700
www.daktronics.com
5. Power up all pylons while DM-100 remains off.
Note: To assure proper addressing, the pylon with communications tied to it (Host) should be powered
up
last. The additional pylons (Clients) are to be powered up first and in any order.
6. Allow about 30 seconds for the pylons to boot up.
7. Power up the DM-100 handheld controller.
Note: Do not press any buttons on the DM-100 while displays and controller are booting up.
8. Allow time for DM-100 to boot up and initialize all pylons.
a. About 1 minute for each wirelessly connected pylon
b. About 1 minute total for a direct-wired pylon system
9. On the DM-100, press Menu > Detect Displays to verify all networks and displays are detected.
10. Verify all displays and lines are detected.
11. Manually send the current prices to the display(s) from the DM-100.
12. Verify that the DM-100 states “Sequence Sent” then “Display Response”.
Use the following as a guide for some Point of Sales Systems, I.E. Radiant
1. Verify the ICON on the PoS register does not say, “Price sign is off-line”, if it does, connect the PoS to the
DM-100.
2. Manually send the current prices to the display(s) from the DM-100. (Override the PoS)
3. Press the Update Display button on the DM-100.
4. Verify DM-100 states “Sending Sequence” then “Display Response”.
5. Re-send current prices from PoS system.
6. Verify price change with PoS.
7. The price on the display should change within a minute.
Note: Some states only allow one price change per day. The procedure above allows system verification
without actually changing the display’s price. If allowed, test the entire system by sending a penny
increase to one of the displays and verify change. Return to correct price.
Note: To retain price updates, you must wait 3 minutes before powering down the gas price displays. Any
changes made to the displays require a 3-minute power on time to commit to memory.
For More Information
Contact the Daktronics Help Desk at 800-325-8766.
For additional information and assistance, contact Gilbarco at 336-547-5000.