beautypg.com

Section 3: maintenance & troubleshooting, 1 component access, 2 led drivers – Daktronics TI-2031 4-Inch LED Bar-Digit Locker Room Clock User Manual

Page 11: 3 replacement parts, Section 3, Maintenance & troubleshooting, Component access, Led drivers, Replacement parts

background image

Maintenance & Troubleshooting

5

Section 3:

Maintenance & Troubleshooting

IMPORTANT NOTES

:


1. Disconnect power before doing any repair or maintenance work on the display.

2. Permit only qualified service personnel to access internal display electronics.

3. Disconnect power when not using the display.

3.1 Component Access

To gain access to the internal components of the display (surface mount):

1. Remove top and bottom screws connecting front and rear cabinet.
2. Separate the front and rear cabinet pieces.
3. Unplug both the signal and power wires from the rear of the display.
4. Remove screws holding circuit board to front of the cabinet.

3.2 LED Drivers

The LED driver performs the task of switching digits on and off. Locker room clock drivers
contain all four LED digits together in one assembly. Locker room clock drivers have two
connectors that provide power and signal to and from the driver:

Connector #

Function

J2

Power Input

TB1

Signal in and out

3.3 Replacement Parts

Refer to the following table for replacement parts.

Description

Daktronics Part #

AS5K 4 Col Clock w/ Driver

0P-1150-0259

Transformer; 12 V AC

T-1118





This manual is related to the following products: