2 flush mount method, Flush mount method – Daktronics TI-2031 4-Inch LED Bar-Digit Locker Room Clock User Manual
Page 10

4
Mechanical & Electrical Installation
2.2 Flush Mount Method
The flush mount cabinet mounts between two 2x4 studs and uses the flush mount rear panel.
1. Drill holes in the wall and install anchors or screws at the locations shown in Drawing
B-1064515. The customer is responsible for providing mounting anchors or screws.
2. Rough out the power supply and signal recess behind cabinet mounting location as
depicted in Drawing B-1064515.
3. Install a 120 V AC, 15 amp electrical outlet on the stud behind the drywall behind the
opening for the clock. This will allow the wall pack transformer to be plugged in and be
out of the way of the clock when the clock is installed in the wall.
4. Route the signal cable to the clock mounting location and allow it to extend at least 12"
(305 mm) beyond the wall.
5. Plug the wall pack transformer into the outlet.
6. Mount the flush-style rear cabinet panel and tighten the anchor screws as needed.
7. Connect the signal wire to plug P-1388 signal terminal on the left side of the display
(when viewed from the rear). Connect the red signal wire to the positive (+) jack labeled
“CL-IN” and the white signal wire to the negative (-) jack labeled “CL-IN”.
8. Plug the wall pack transformer into the power jack located below the signal terminal.
9. Line up and mate the rear and front cabinet pieces. Attach the pieces together with
included screws.