LOG SIZING REQUIREMENTS

Minimum Firebox Size

Log

Front

Rear

Size

Height Depth Width

Width*

18"

17"

14"

24"

20"

24"

17"

14"

28"

21"

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Log Size

Side Wall

Ceiling

18", 24"

16"

42"

NOTICE: State or local codes
may only allow operation of
this appliance in a vented con-
figuration. Check your state or
local codes.

WARNING: Before installing

in a solid fuel burning fireplace,
the chimney flue and firebox must
be cleaned of soot, creosote,
ashes and loose paint by a quali-
fied chimney cleaner. Creosote
will ignite if highly heated. A dirty
chimney flue may create and dis-
tribute soot within the house. In-
spect chimney flue and firebox
for damage. If damaged, repair
flue before operating heater.

WARNING: Seal any fresh

air vents or ash clean-out doors
located on floor or wall of fire-
place. If not, drafting may cause
pilot outage or sooting. Use a
heat-resistant sealant. Do not
seal chimney flue damper.

WARNING: Never install the

heater
• in a bedroom or bathroom un-

less installed as a vented ap-
pliance (Variable Manually-
Controlled Models Only) (see
page 12)

• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the heater

• in high traffic areas
• in windy or drafty areas

INSTALLATION

Continued

CAUTION: This heater cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.)
in the air exist, may discolor
walls or cause odors.

IMPORTANT:

Vent-free heaters add moisture to

the air. Although this is beneficial, installing heater
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Air
for Combustion and Ventilation
, page 5.

CHECK GAS TYPE

Use only the correct gas type (natural or pro-
pane/LP) for your unit. If your gas supply is not
correct, do not install heater. Call dealer where
you bought heater for proper type heater.

WARNING: This appliance is

equipped for (natural or propane/
LP) gas. Field conversion is not
permitted.

INSTALLATION AND CLEARANCES
(Vent-Free Operation Only)

WARNING: Maintain the

minimum clearances. If you can,
provide greater clearances from
floor, ceiling, and adjoining wall.

*Measured at 14" Depth