LIGHTING
INSTRUCTIONS
WARNING
• If fireplace has glass doors,
never operate this heater with
glass doors closed. If you op-
erate heater with doors closed,
heat buildup inside fireplace
will cause glass to burst. Make
sure there are no obstructions
across openings of fireplace.
• You must operate this heater
with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be
present. Open damper or win-
dow to vent smell. This will only
last a few hours.
Note:
Home owners generally prefer to oper-
ate their heater with the chimney damper
closed. This will put all the heat into the room.
However, there may be times you will desire
the full flames of the HI heat setting but will
find the heat output excessive. You can open
the chimney damper (if you have one) fully or
partially to release some of the heat.
WARNING: Damper handle will
be hot if heater has been running.
1. STOP! Read the safety information,
page 20, column 2.
2. Make sure equipment shutoff valve is
fully open.
3. Turn control knob clockwise
to the
OFF position.
4. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information, page 20, column 2. If
you don’t smell gas, go to the next step.
OPERATING HEATER
Continued
5. Turn control knob counterclockwise
to the PILOT position. Press in control knob
for five (5) seconds (see Figure 28).
Note:
You may be running this heater for
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
• If control knob does not pop out when re-
leased, contact a qualified service person
or gas supplier for repairs.
6. With control knob pressed in, press and re-
lease ignitor button. This will light pilot. The
pilot is attached to the front burner. If needed,
keep pressing ignitor button until pilot lights.
Note:
If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 22.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note:
If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute for sys-
tem to reset before lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The burners should
light. Set control knob to any heat level be-
tween HI and LO.
CAUTION: Do not try to ad-
just h eating levels by using the
equipment shutoff valve.
LO
HI
OFF
Pilo
t
Figure 28 - Control Knob and Ignitor
Button Location
Control Knob
Ignitor Button
Figure 29 - Pilot
Thermocouple
Ignitor
Electrode
Pilot Burner
Propane/LP
Natural Gas