beautypg.com

Installation – Desa CLD3018PTA User Manual

Page 13

background image

www.desatech.com

113101-01A

13

INSTALLATION

Continued

IMPORTANT:

Make sure the heater burners are

level. If heater is not level, heater will not work
properly. For thermostat models, avoid damage to
thermostat bulb. Avoid nicks or sharp bends in
thermostat bulb wire. Keep thermostat bulb in
mounting bracket until ready to mount base to
floor. See Optional Positioning Of Thermostat
Sensing Bulb
, page 28.

Installation Items Needed
• hardware package (provided with heater)
• approved flexible gas hose (not provided) (if

allowed by local codes)

• sealant (resistant to propane/LP gas, not provided)
• electric drill with 3/16" drill bit
• flathead screwdriver
1. Apply pipe joint sealant lightly to male threads

of the fitting to be threaded into gas regulator.
Connect approved flexible gas hose to gas
regulator of heater (see Figure 11).
IMPORTANT:

Hold gas regulator with

wrench when connecting flexible gas hose.

2. Locate masonry screws in hardware package.
3. Position heater base assembly in fireplace.
4. Place logs in their proper position on heater

base (see Installing Logs, page 16).

5. Center heater base and logs front-to-front and

side-to-side in fireplace.

6. Carefully remove logs without moving

heater base.

7. Mark screw locations through holes in mount-

ing brackets (see Figure 12). If installing in a
brick-bottom fireplace, mark screw locations
in mortar joint of bricks.

8. Remove heater base from fireplace.
9. Drill holes at marked locations using 3/16"

drill bit.

10. Attach base assembly to fireplace floor using

two masonry screws (in hardware package)
(see Figure 12).

Figure 12 - Attaching Base Assembly to

Fireplace Floor

Heater Gas
Regulator

Flexible Gas Hose
(if allowed by local codes)

Figure 11 - Attaching Flexible Gas Hose

to Heater Gas Regulator

Fitting

Masonry
Screw

Mounting
Bracket

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 1/2" NPT (National
Pipe Thread) inlet connection to
the pressure regulator.

WARNING: A qualified ser-

vice person must connect
heater to gas supply. Follow all
local codes.

CAUTION: Never connect

propane/LP heater directly to the
propane/LP supply. Propane/LP
heaters require an external regu-
lator (not supplied). Install the
external regulator between the
heater and propane/LP supply.

WARNING: For natural gas

units, never connect heater to
private (non-utility) gas wells.
This gas is commonly known as
wellhead gas.

This manual is related to the following products: