beautypg.com

Installation – Desa CLD3018PTA User Manual

Page 15

background image

www.desatech.com

113101-01A

15

CHECKING GAS CONNECTIONS

WARNING: Test all gas pip-

ing and connections , internal
and external to unit, for leaks
after installing or servicing. Cor-
rect all leaks at once.

WARNING: Never use an

open flame to check for a leak.
Apply a commercial leak detec-
tion solution to all joints.
Bubbles forming show a leak.
Correct all leaks at once.

CAUTION: For propane/LP

units, make sure external regula-
tor has been installed between
propane/LP supply and heater.
See guidelines under Connecting
to Gas Supply

, page 13.

INSTALLATION

Continued

PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect appliance with its appliance main

gas valve (control valve) and equipment shutoff
valve from gas supply piping. Pressures in ex-
cess of 1/2 psig will damage heater regulator.

2. Cap off open end of gas pipe where equip-

ment shutoff valve was connected.

3. Pressurize supply piping system by either

opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve lo-
cated on or near gas meter for natural gas, or
using compressed air.

4. Check all joints of gas supply piping system.

Apply a commercial leak detection solution
to all joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff valve

to gas supply. Check reconnected fittings for
leaks.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 15).
2. Pressurize supply piping system by either

opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve lo-
cated on or near gas meter for natural gas, or
using compressed air.

3. Check all joints from gas meter (natural gas)

or propane/LP supply to equipment shutoff
valve (see Figure 16 or 17). Apply a commer-
cial leak detection solution to all joints.
Bubbles forming show a leak.

4. Correct all leaks at once.

Figure 15 - Equipment Shutoff Valve

ON

POSITION

OFF

POSITION

Open

Closed

Equipment
Shutoff
Valve

Equipment Shutoff Valve

Propane/LP
Supply Tank

Control Valve
Location

Figure 17 - Checking Gas Joints

(Natural Gas Only)

Gas
Meter

Equipment Shutoff Valve

Control Valve Location

Figure 16 - Checking Gas Joints

(Propane/LP Gas Only)

This manual is related to the following products: