Automatic/manual mode – Comtech EF Data UT-4500 Series User Manual
Page 88

UT4500 Series Up Converter
MN/UT4500.IOM
Remote Control
Revision 2
70
Command
Details
Initialize Command:
Confirmation: >DEV/ICT_xx_yy'cr''lf']
Initialize Status:
Confirmation: >DEV/ICT_xx_yy'cr''lf']    xx = chain position = 01 to 12, or BU. Where BUselects the      converter as the backup.    yy = chain length for xx = BU (i.e. Backup converter) 01 to 12.    yy = unused if xx = 01 to 12 (i.e. chain converter)  Example 1:  The following command assigns the converter chain position "1".    The following command assigns the receiving converter as the backup      converter in a 1:8 system.    5.6.3.2 A UTOMATIC /M ANUAL  M ODE   This command provides for automatic switching by the backup converter if both units are  Command  Details  Automatic Mode:  Confirmation: >DEV/SAM_xx_y'cr''lf']  Automatic Status:  Confirmation: >DEV/SAM_xx_y'cr''lf']  Where: xx = 01 to 12, converter number  y = A for Auto; M for Manual   
 
Example 2: 
It should be reiterated that only the converter physically located at the top of a redundant 
rack should be assigned as the Backup unit. Likewise, assignment of chain positions in a 
redundant rack should be made according to the physical allocation of each converter in 
the rack (i.e. The top converter should be the Backup, the second converter should be 
assigned chain position 1, the third converter position 2, etc.). 
in the Redundancy Mode. This command is only accepted by the backup converter. If a 
chain converter is set in Manual Mode, the backup converter will log the occurrence and 
not act upon further information from the converter until put into Automatic Mode. The 
default is off. 
 
