Command / response pairs, Utility commands, Time – Comtech EF Data UT-4500 Series User Manual
Page 81: Date, Physical address, Baud rate
UT4500 Series Up Converter
MN/UT4500.IOM
Remote Control
Revision 2
63
5.6 C
OMMAND
/ R
ESPONSE
P
AIRS
5.6.1 U
TILITY
C
OMMANDS
5.6.1.1 T
IME
Command
Details
Set Time:
hh = Hour*
Confirmation: >DEV/TIM_hh:mm:ss'cr''lf']
mm = Minutes ss = Seconds
Retrieve Time:
Confirmation: >DEV/TIM_hh:mm:ss'cr''lf']
* 24 hour military time is used.
5.6.1.2 D
ATE
Command
Details
Set Date:
mm = Month Confirmation: >DEV/DAT_mm/dd/yy'cr'lf'] dd = Day yy = Year Retrieve Date: Confirmation: >DEV/DAT_mm/dd/yy'cr''lf'] 5.6.1.3 P HYSICAL A DDRESS The default Physical Address from is 1. Command Details Set Physical Address: xxx = 1 to 255 Confirmation: >DEV/SPA_xxx'cr''lf'] Retrieve Phys. Addr: Confirmation: >DEV/SPA_xxx'cr''lf'] 5.6.1.4 B AUD R ATE The default baud rate is 9600. Command Details Set Baud Rate: xxxx = 1200, 2400, 4800, 9600, 19K2, or 38K4 Confirmation: >DEV/SBR_xxxx'cr''lf'] Retrieve Baud Rate: Confirmation: >DEV/SBR_xxxx'cr''lf']