Rf converter module, Synthesizer sum loop module, Synthesizer fine step module – Comtech EF Data UT-4500 Series User Manual
Page 106: Reference oscillator module, Temperature fault

UT4500 Series Up Converter
MN/UT4500.IOM
Maintenance and Troubleshooting
Revision 2
88
7.2.3.3 RF C
ONVERTER
M
ODULE
IFLO LOCK DETECT:
A fault (“FT”) indicates that the IFLO is not locked. Check all connections to the 
converter module to make sure they are secure. If the fault still exists, remove the 
Converter Module and return it to Comtech EF Data for repair. 
7.2.3.4 S
YNTHESIZER
S
UM
L
OOP
M
ODULE
SUM LOOP DETECT:
A fault (“FT”) indicates that the sum loop is not locked. Check all connections to 
the converter module to make sure they are secure. If the fault still exists, remove 
the Sum Loop Module and return it to Comtech EF Data for repair. 
7.2.3.5 S
YNTHESIZER
F
INE
S
TEP
M
ODULE
COARSE LOOP DETECT:
A fault (“FT”) indicates that the coarse loop is not locked. Check all connections 
to the converter module to make sure they are secure. If the fault still exists, 
remove the Fine Step Module and return it to Comtech EF Data for repair. 
FINE LOOP DETECT:
A fault (“FT”) indicates that the fine loop is not locked. Check all connections to 
the converter module to make sure they are secure. If the fault still exists, remove 
the Fine Step Module and return it to Comtech EF Data for repair. 
7.2.3.6 R
EFERENCE
O
SCILLATOR
M
ODULE
REFERENCE LOCK DETECT:
A fault ("FT") indicates that the reference oscillator detected an external 
reference, but could not lock to it. Disconnect the external reference. If the fault 
still exists, remove the Reference Module and return it to Comtech EF Data for 
repair. 
7.2.3.7 T
EMPERATURE
F
AULT
CONVERTER OVER TEMPERATURE FAULT:
A fault ("FT") indicates that the converter is over temperature. Turn the prime 
power switch off and return the converter to Comtech EF Data for repair. 