ECL Baseband DATA I/O (B, Common, and A)
The ECL interface is provided on a 50-pin female D connector. The switch DATA I/O
connectors provide the baseband data interface from the DTE equipment to the switch,
and from the switch to the prime and backup modems. Screw locks are provided for
mechanical security of the mating connector.
Signal Function
Name
Pin #
GROUND GND
1,
2
SEND DATA (SD)
TXD-A (ECL-)
TXD-B (ECL+)
37
38
TERRESTRIAL TIMING (TT)
TXO-A (ECL-)
TXO-B (ECL+)
4
5
SYNC TX FRAME (TX SYNC)
SD-A (ECL-)
SD-B (ECL+)
34
18
EXTERNAL BUFFER CLOCK EXC-A
(ECL-)
EXC-B (ECL+)
35
19
RECEIVE DATA (RD)
RXD-A (ECL-)
RXD-B (ECL+)
39
40
RECEIVE TIMING (RT)
RXC-A
RXC-B
23
24
SYNC RX FRAME (RX SYNC)
RD-A
RD-B
36
20
SEND TIMING (ST)
RXC-A
RXC-B
21
22
RECEIVE LINE SIGNAL DET
RXO-A
RXO-B
6
7
ADPCM1 AUDIO IN
A1I-A
A1I-B
45
29
ADPCM1 AUDIO OUT
A1O-A
A1O-B
46
30
ADPCM2 AUDIO IN
A2I-A
A2I-B
47
31
ADPCM2 AUDIO OUT
A2O-A
A2O-B
48
32
BACKWARD ALARM 1 OUT
BWO1-C
BWO1-NC
BWO1-NO
8 (See Note 1)
25
41
BACKWARD ALARM 2 OUT
BWO2-C
BWO2-NC
BWO2-NO
9 (See Note 1)
26
42
BACKWARD ALARM 3 OUT
BWO3-C
BWO3-NC
BWO3-NO
10 (See Note 1)
27
43
BACKWARD ALARM 4 OUT
BWO4-C
BWO4-NC
BWO4-NO
11 (See Note 1)
28
44