beautypg.com

Summary of specifications, Chapter 7. summary of specifications – Comtech EF Data CRS-100 User Manual

Page 35

background image

MN-CRS100.IOM 7–1

Chapter 7. SUMMARY OF

SPECIFICATIONS

Equipment Type

1:1 Redundancy Switch

Modems
Supported

CDM-500, CDM-550 and CDM-550T Digital Satellite Modems

Operating Modes

Fully automatic
Manual (via the front panel of the Online Modem, or via the Modem’s
remote control interface )

Architecture

Full bridging architecture, with configuration synchronization
Tx Clock and Data signals fed to both Online and Standby units
Rx IF signal fed to both Online and Standby units
Continuous fault comparison of Online and Standby units
The configuration of Online and Standby units synchronized via the
Auxiliary Serial link between the two Modems

Switch Conditions

Switchover initiated following:
Unit faults only, or:
Unit faults or Receive Traffic Faults, or:
Unit faults or Transmit Traffic Faults, or:
Unit faults or Receive or Transmit Traffic Faults

Fault detection
time

0.5 seconds maximum

Switchover time

Within 0.1 seconds of fault detection

Data Interface
Types

EIA-422/EIA530 DCE (also supports X.21 DCE and DTE)
V.35 DCE
Synchronous EIA-232
Asynchronous EIA-232 (maximum data rate: 56 kbaud, and when
used with CDM-550 or CDM-550T only)
Automatic selection performed by modem

Pinout

Per EIA-530 (25 pin ‘D’ type female)

IF Switching
/Splitting

Tx IF: Switched by RF relay (0.3 dB max loss)
Rx IF: Passive power splitting (3.5 dB max loss)

IF Impedance

Both 50 and 75

Ω supported

IF Connectors

BNC female