Rev. 1.2

5–1

Chapter 5. CONNECTOR PINOUTS

Table 5-1. Data Connector - 25 Pin ‘D’ Type Female

Pin

Generic Signal description

Direction

EIA-422/

EIA 530

V.35

EIA-232

Circuit

No

1 Shield

-

Shield

FG

AN

101

2

Transmit Data A

DTE to Modem

SD A

SD A

BA

103

3

Receive Data A

Modem to DTE

RD A

RD A

BB

104

7

Signal Ground

-

SG

SG

AB

102

8

Receiver Ready A

Modem to DTE

RR A

RLSD *

CF

109

9

Receive Clock B

Modem to DTE

RT B

SCR B

-

115

10

Receiver Ready B

Modem to DTE

RR B

-

-

109

11

Transmit Clock B

DTE to Modem

TT B

SCTE B

-

113

12

Internal Transmit Clock B

Modem to DTE

ST B

SCT B

-

114

14

Transmit Data B

DTE to Modem

SD B

SD B

-

103

15

Internal Transmit Clock A

Modem to DTE

ST A

SCT A

DB

114

16

Receive Data B

Modem to DTE

RD B

RD B

-

104

17

Receive Clock A

Modem to DTE

RT A

SCR A

DD

115

23

External Carrier Off
(EIA-232 ‘1' or TTL ‘low’ )

DTE to Modem

-

-

-

-

24

Transmit Clock A

DTE to Modem

TT A

SCTE A

DA

113

NOTES:

* Receiver ready is an EIA-232-level control signal on a V.35 interface

‘B’ signal lines are not used for EIA-232 applications

For X.21 operation, use the EIA-422 pins, but ignore Receive Clock if the Modem is DTE, and ignore Transmit clocks if the
Modem is DCE