Comtech EF Data DD240XR Rev Е User Manual
Page 69

DD240XR High-Speed Digital Demodulator
User Interfaces
MN-DD240XR – Rev. E
4-49
The first token will be converted into decimal based numerator.
The second token will be converted into a decimal based denominator.
"
SYNTAX OCTET STRING (SIZE (20))
RadString ::= TEXTUAL-CONVENTION
DISPLAY-HINT
"255a"
STATUS
current
DESCRIPTION
"ASCII String."
SYNTAX
OCTET STRING
RadVoltageLevel ::= TEXTUAL-CONVENTION
DISPLAY-HINT
"d-1"
STATUS
current
DESCRIPTION
"Voltage level in tenths of a volt."
SYNTAX
INTEGER
-----------------------------------------------------------------------------
-- demodulator
networkSpec OBJECT-TYPE
SYNTAX INTEGER {
dvb(1),
dvbS2BsNbc(2),
dtvAmcNbc(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Selects network specification.
"
::= { demodulator 1 }
frequency OBJECT-TYPE
SYNTAX Unsigned32 (50000000..180000000|950000000..2150000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Selects frequency in Hz.
I-F valid values are: 50000000..180000000
L-Band valid values are: 950000000..2150000000
"
::= { demodulator 2 }
modulation OBJECT-TYPE
SYNTAX INTEGER {
bpsk(2),
qpsk(4),
psk8(8),
qam16(16)
apsk16(32)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Selects the modulation type.
Changing modulation type will affect the symbol rate and data rate,
the IFEC may also be constrained or altered based upon modulation choices.
"
::= { demodulator 3 }
innerFecRate OBJECT-TYPE