Comtech EF Data DD240XR Rev Е User Manual
Page 45

DD240XR High-Speed Digital Demodulator
User Interfaces
MN-DD240XR – Rev. E
4-25
User4 reset value = DES
This is the encryption method used to provide a key for
the message privacy. If a group access requires privacy
DES must be selected. The host station and the
equipment must both use the same method.
USER RESET:
Pressing enter will reset the ACCESS GROUP, AUTH
PASSWORD, PRIV PASSWORD, AUTHENTICATION,
and PRIVACY for the current user submenu.
HW/FW CONFIG (Menu):
Allows the user to view and edit the hardware and
firmware configurations.
DD240:
{EVALUATION, SERIES 100, SERIES 200,
SERIES 300, SERIES 350}
This screen displays the feature set enabled in the
software.
FIRMWARE REV:
{F04677.Y.MMDDYY}
Displays the main board assembly number where
4677.XX.XX.XX = the firmware set release number.
M&C REV:
{X.XX}
This screen is used to display the M&C Revision.
MAIN BOARD:
SERIAL NUMBER#:
Displays the main board serial number.
PC NUMBER:
{PC/XXXXNN}
Displays the main board printed circuit card number
where XXXX = the card number, and NN = the revision
number.
ASSEMBLY NUMBER#:
{AS/XXXXNN}
Displays the main board assembly number where XXXX
= the assembly number, and NN = the revision number.
DEMOD BOARD:
FIRMWARE REV:
{XXXXXXXX}
Displays the Demod Board Firmware Revision Number.
TYPE:
These 16 alphanumeric characters display the Hardware
Daughter Card Identifier.
BOARD ID:
{0 - 7}
Displays the Communication ID for Internal Demod
Daughter Card.
TERR INTFC BRD:
FIRMWARE REV:
Displays firmware revision of terrestrial interface board.