Temperature monitoring, Changing lock settings, Units – CompX eLock Temperature Monitoring Programming User Manual
Page 3: Set time (st time), Alarm (alrm)

Temperature Monitoring
5.
The display will show the next available slot to program into.
Hit (All entries done by slots will need to be logged.)
Take the next available slot by pushing or program
by specific slot by scrolling with the up and down buttons.
6.
The unit will display “READy."
7.
Enter PIN followed by # or present card.
8.
Unit will say “DONE.”
9.
Unit will return to normal operating mode, showing alternating
time and temp.
deleting users or supervisors:
1.
Enter supervisor code / card and press #. Display will
show “Supr.”
2.
Press and hold * for about three seconds.
3.
Display will show “DEL." Hit .
4.
At this point you can enter the PIN followed by # or present
the card for the credential you want to remove.
a. If you want to delete by slot assignment, hit
after you see “DEL” in the display.
b. The units will display “DL-Who." Use the up or down
key to select the slot you want to clear and hit .
c. Unit will display “ok-y” and alternate “slot.”
d. Hit to confirm. Unit will show “Done.”
Changing Lock settings
Enter supervisor code / card and press #. Display will show “Supr.”
Press and hold for about three seconds. Display will show
“ALRM” – use the up or down arrows to toggle between Units, St Time
and ALRM modes. Hit on desired mode.
units
If Units is chosen, the eLock will allow you to select either F˚ or
C.˚ Scroll using the up or down arrows until “Units” appears on the
display and hit . Using the up or down key, select either F˚ or C˚
and press . The display will show “DONE” momentarily and then
revert back to time and temperature.
set tiMe (st tiMe)
If St Time is chosen, the eLock will allow you to adjust the time and
date. Scroll using the up or down arrows until “St Time” appears on
the display and hit .
Set Year using up and down arrows. Press .
Set Month using up and down arrows. Press .
Set Day using up and down arrows. Press .
Set Hour using up and down arrows. Press .
Set Minutes using up and down arrows. Press .
The display will show “DONE” momentarily and then revert back to
time and temperature.
AlArM (AlrM)
If ALRM is chosen and the alarm is Disabled, the LCD screen will
read “Enable.” Press to confirm ALRM enabling.
a. Next screen will display “Limits” which allows you set
the upper and lower limits of the alarm mode. Press
to begin Limits programming
b. Set minimum temperature and press
c. Set maximum temperature and press
d. The display will show “DONE” momentarily and then
revert back to time and temperature
If ALRM is chosen and ALRM is Enabled, the LCD screen will display
Limits. Use the up or down arrows to toggle between Limits, disable,
A-Vol, MUTE, and R-SET. Select desired mode and press .