Able 8 on pag, D ratio (see table 8 on pag, Table 8 on pa – Compuprint 6314 CZL User Manual
Page 49: D (see table 8 on pag, Enabled (see table 8 on pag

CZL – Programmer Manual
49
Extensions, UPC A, PostNet. Each of these is identified with a numeral or a letter that coincides
with the parameter to be inserted in the ^Bx command on page 18 (see table 8).
Each type of bar-code has its own characteristics: some are fixed length, others not, some accept all
characters, and others only upper case letters or numerals.
The widths of the bars are defined according to set ratios. Some bar-codes require a fixed ratio to be
read properly, while for others the ratio can vary from 2 to 3 without affecting the reliability of
readings.
x
Description
Ratio
ASCII characters allowed
203
Length
Check
digit
2 Interleaved
2/5 2
÷3 48÷57
Variable Optional
3 Code
39 2
÷3
32, 36, 37, 43, 45
÷57, 65÷90
Variable Optional
8 EAN
8 Fixed
48
÷57
7 Yes
9 UPC
E Fixed
48
÷57
10 Yes
C Code
128 Fixed
32
÷93, 95÷126
Variable Optional
E EAN
13 Fixed
48
÷57
12 Yes
K ANSI
Codabar 2
÷3
36, 42, 43, 45
÷58, 65÷69, 78, 84
Variable Optional
M MSI 2
÷3 48÷57 1÷14
Optional
S UPC/EAN
Extensions Fixed
48
÷57
2 or 5
No
U UPC
A Fixed
48
÷57
11 Optional
Z PostNet Fixed
48
÷57
Variable No
table 8 – Bar-code specifications
203